Part No: AN886Issued year: 2017File size: 1mbFile type: pdf
This application note describes the extraction of 96 licit and illicit drugs of abuse from urine prior to UPLC-MS/MS analysis using EVOLUTE® HYDRO CX 96-well plates.
EVOLUTE® HYDRO CX plates offer an efficient way to perform hydrolysis in the well of the extraction plate. This method provides high analyte recovery, reduced extraction time due to the elimination of a sample transfer step as well as the elimination of the column conditioning and equilibration steps, and a reduced risk for sample carryover or cross-contamination due to the elimination of the sample transfer step.
Part No: P138Issued year: 2015File size: 0.82mbFile type: pdf
This poster demonstrates a fast, reliable protocol to extract multiple drug of abuse panels from whole blood using a common supported liquid extraction methodology. This benefits laboratory workflow where multiple assays are run each day, saving both worker hours and
consumable costs.
SOFT 2015
ASMS 2016
TIAFT 2016
Part No: AN768Issued year: 2013File size: 1.86mbFile type: pdf
This application note describes a Supported Liquid Extraction (SLE) protocol for the extraction of various drugs of abuse from hydrolyzed urine prior to LC-MS/MS analysis.
drugs of abuse, sle, multiclass
Part No: AN766Issued year: 2013File size: 1.26mbFile type: pdf
This application note describes effective and efficient protocols for extraction of cocaine and its major metabolites optimized for sample loading volumes of either 400 μL or 1 mL using ISOLUTE SLE+ supported liquid extraction columns. The simple sample preparation procedure delivers clean extracts and analyte recoveries greater than 83% with RSDs of <7% for all analytes.
Part No: AN872Issued year: 2017File size: 1.08mbFile type: pdf
This application note describes the extraction of cocaine and selected metabolites from oral fluid matrix following the collection with the NeoSalTM device, prior to GC/MS analysis.
Part No: AN803Issued year: 2013File size: 1.28mbFile type: pdf
This application note describes effective and efficient protocols optimized for loading volumes of either 400 μL or 1 mL using ISOLUTE SLE+ supported liquid extraction columns. The simple sample preparation procedure delivers clean extracts and analyte recoveries greater than 85% with RSDs of <10% for all analytes.
Part No: AN802Issued year: 2013File size: 1.19mbFile type: pdf
This application note describes effective and efficient protocols optimized for sample volumes of either 400 μL or 1 mL using ISOLUTE SLE+ supported liquid extraction columns. The simple sample preparation procedure delivers clean extracts and analyte recoveries greater than 80% with RSDs of <10% for all analytes.
Part No: AN856Issued year: 2015File size: 0.7mbFile type: pdf
This application note describes the extraction of cocaine and major metabolites from whole blood, prior to GC/MS analysis. This protocol also allows the simultaneous extraction of various other drugs of abuse classes: amphetamines, barbiturates, benzodiazepines and opiates.
ISOLUTE® SLE+ columns with 1 mL sample capacity are used to extract whole blood samples following a straightforward sample dilution. No protein precipitation or other pre-treatment is required prior to sample loading. The sample preparation procedure delivers clean extracts, good recoveries and RSD values and LLOQs from 20 ng/mL (analyte dependant).