Designed for high throughput laboratories, the Biotage® SPE Dry 96 and Biotage® SPE Dry 96 Dual Sample Concentrator Systems provide efficient solvent evaporation in microplate format and are compatible with 24-, 96- and 384-well collection plates. Heated gas flow from above and below the collection plate ensures efficient solvent evaporation.
Technology | Heated gas delivery above and below wells speeds evaporation |
Number of samples | Models for one or two 96 well plates |
Format | 8 x 12 well microplates and deep-well plates |
Timer | Manual |
Max. sample volume | 10 mL collection plates |
Final endpoint volumes | - |
Capacity | 24, 48, 96 or 384 well plates |
Gas temperature | 60 °C (upper head); 80 °C (lower head) |
Gas supply requirements | Minimum 15 psi, maximum 50 psi |
Gas flow | Operating flow rate 25 to 100 L per minute (LPM) |
Exhaust | - |
Power Requirements | 100/120 VAC 50/60 Hz 220/240 VAC 50/60 Hz 405 W nominal power |
Fuses | 5A T250V |
Dimensions (WxDxH) | 25.4 x 38.1 x 40 cm (dual) 10" x 15" x 15.7" 24.2 x 30.6 x 40 cm |
Weight | 13.9 kg/31 lbs |
Certifications | EN61326 (1997 w/A1: 98 & A2: 01) Class A |
Max Sound Level | 65 dB (A) |
This application note describes a procedure for sample
pre-treatment and extraction of a panel of 49 drugs of
abuse from human hair, using Biotage® Lysera for matrix
micropulverization, prior to clean up using ISOLUTE® SLE
supported liquid extraction. The application note contains
procedures optimized for 400 μL capacity column format and
200 μL and 400 μL supported liquid extraction plate formats,
for higher throughput applications. The methodology delivers
clean extracts and analyte recoveries mostly greater than
80% with RSDs lower than 10% for all analytes and LLOQ from
1 ng/mL.
Tags: 6-MAM,
7-Aminoclonazepam,
7-Aminoflunitrazepam,
96-well plate,
Alprazolam,
Amphetamine,
Application Notes,
Bromazepam,
Buprenorphine,
Clinical,
Clonazepam,
Cocaine,
Codeine,
Column,
Diazepam,
Dihydrocodeine (DHC),
Drugs of Abuse,
EDDP,
English,
Estazolam,
Fentanyl,
Flunitrazepam,
Flurazepam,
Hair,
Hydrocodone,
Hydromorphone,
Ketamine,
Lorazepam,
Lysergic acid diethylamide (LSD),
MDA,
MDMA,
Mephedrone,
Methadone,
Midazolam,
Morphine,
Nitrazepam,
Norbuprenorphine,
Nordiazepam,
Norfentanyl,
Norketamine,
Oxazepam,
Oxycodone,
Oxymorphone,
Phencyclidine (PCP),
Temazepam,
Triazolam,
UPLC-MS/MS,
Zaleplone,
Zolpidem,
Zopiclone,
α-OH alprazolam
This application note describes a streamlined procedure for
sample pre-treatment and extraction of a panel of 49 drugs
of abuse from human hair, using Biotage® Lysera for matrix
micropulverization, prior to direct transfer to clean up using
ISOLUTE® SLE supported liquid extraction.
Tags: 96-well plate,
Alprazolam,
Amphetamine,
Application Notes,
Bromazepam,
Buprenorphine,
Clinical,
Clonazepam,
Cocaine,
Codeine,
Column,
Diazepam,
Dihydrocodeine (DHC),
Drugs of Abuse,
EDDP,
English,
Estazolam,
Fentanyl,
Flunitrazepam,
Flurazepam,
Hair,
Hydrocodone,
Hydromorphone,
Ketamine,
Lorazepam,
Lysergic acid diethylamide (LSD),
MDA,
MDEA,
MDMA,
Mephedrone,
Methamphetamine,
Methedrone,
Midazolam,
Morphine,
Nitrazepam,
Norbuprenorphine,
Nordiazepam,
Norfentanyl,
Norketamine,
Oxazepam,
Oxycodone,
Oxymorphone,
PCB,
Temazepam,
Triazolam,
UPLC-MS/MS,
Zaleplone,
Zolpidem,
Zopiclone
New, novel benzodiazepines have become some of the most abused unique psychoactive substances seen today. In the United States, these compounds are not approved for prescription use. Therefore, the demand for testing of these drugs has rapidly increased, both in the United States and worldwide. Urine and whole blood are common matrices of choice for forensic laboratories as they can be easy to collect, and they provide relevant information regarding recent or active use of illicit materials.
Tags: 96-well plate,
Forensic,
LC-MS/MS,
Posters,
Synthetic Benzodiazepines,
Urine,
Whole blood
Hydroxychloroquine (HCQ) and chloroquine (CQ) are common antimalarial drugs with long half-lives. They are currently being tested as potential treatments for COVID-19. Due to their high publicity in the media, many forensic toxicologists are working on developing methods to extract and detect these compounds in different matrices to understand the adverse effects, potential toxicity, and drug interactions associated with these drugs. These compounds are not typically included in general unknown screens. A simple sample preparation procedure that delivers clean extracts and analyte recovery greater than 90% for CQ and greater than 82% for HCQ with minimum matrix effects and high process efficiency was developed.
Tags: Biological fluids,
Chloroquine (CQ),
Clinical,
Hydroxychloroquine (HCQ),
LC-MS/MS,
Posters
LC-MS/MS analysis of volatile analytes is problematic when 96-well plates are used. Solid phase extraction of urine with high drug concentrations can cause contamination of the elution solvent during evaporation as the compounds volatilize then redistribute in adjacent wells.This phenomenon, known as “evaporative crosstalk”, can generate false positive results.
Tags: Amphetamines,
Forensic,
LC-MS/MS,
Methamphetamine,
Posters
Routine testing for drugs of abuse (DOA) in urine is commonly
performed by many clinical, forensic, and pain management
laboratories. The method of testing varies but can often provide
unwanted load stress for day-to-day operation in labs. Most seek
simplified yet reliable and robust modes of sample preparation and
analysis. ASMS, 2020.
Tags: 96-well plate,
Amitriptyline,
Clinical,
Codeine,
Drugs of Abuse,
Hydromorphone,
Lorazepam,
Morphine,
Naloxone,
Norbuprenorphine,
Oxazepam,
Oxymorphone,
Posters,
THC-COOH,
Urine
Evaporative crosstalk is well-to-well cross contamination
during extract evaporation after SLE or SPE extraction in a 96
well plate. It is often observed with volatile analytes like
methamphetamine and amphetamine, but it can also occur
with other drugs and metabolites when urine samples have
very high analyte concentrations. ASMS, 2020.
Tags: Amphetamine,
Benzoylecgonine,
Drugs of Abuse,
Forensic,
Hydromorphone,
MDA,
MDEA,
MDMA,
Methamphetamine,
Morphine,
Posters,
Urine
Monitoring estrogenic compounds such as Estrone (E1), Estradiol
(E2), and Estriol (E3) in human serum is essential in clinical research and diagnostics. Detection in men, post-menopausal women and children requires very low limits of detection (LODs) which can be challenging.
Tags: 96-well plate,
Clinical,
Estrogens,
LC-MS/MS,
Posters,
Serum
Biotage® SPE Dry 96 and SPE Dry 96 Dual Sample Concentrators are suitable for evaporation of microplate samples across a broad range of formats. By delivering heated gas above and below each well, SPE Dry 96 systems dry samples quickly maintaining tight temperature control at user selected settings. Designed for high throughput sample processing,
SPE Dry systems have simple front panel controls and use removable gas delivery assemblies for fast adjusting and cleaning.
Tags: English,
Product Notes
Synthetic benzodiazepines are becoming more abused and are considered “legal highs”. Many forensic laboratories are finding more and more of these compounds in postmortem and impairment...
08 January 2020The testing of alternative matrices in forensic and/or clinical toxicology is gaining popularity, partly due to less invasive means of collection. Matrices such as hair or nail can provide a more r...
20 November 2019These two application notes describe alternative approaches to the extraction of a suite of regulated veterinary growth promoters (including steroids, stilbenes and resorcylic acid lactones) from a...
27 September 2019Two new application notes from Biotage describe both manual and automated procedures for sample pre-treatment and extraction of a panel of 19 steroid hormones from human urine, using EVOL...
18 September 2019The application note demonstrates an efficient sample prep workflow for horse hair samples utilizing the Biotage® Lysera for matrix pre-treatment, ISOLUTE® SLE+ for extraction and the Biota...
27 June 2019This application note describes a procedure for sample pre-treatment and extraction of THC and metabolites from human hair, using Biotage® Lysera for matrix pulverization of the sampl...
26 June 2019This application note describes the fully-automated extraction of opiates from acid-hydrolyzed urine and non-hydrolyzed urine prior to GC/MS analysis. The methods were automated using &nb...
20 June 2019The testing of alternative matrices in forensic and/or clinical toxicology is gaining popularity, partly due to less invasive means of collection. Matrices such as hair or nail can ...
24 April 2019This application note demonstrates the applicability of our newest sample preparation consumable, ISOLUTE® HYDRO DME+ for in-situ hydrolysis and clean-up of urine samples, for the analysis of a...
04 February 2019This video outlines Application AN894, where angiotensin and aldosterone are extracted in the same process using EVOLUTE® EXPRESS ABN.
06 December 2018These two new application notes from Biotage describe procedures for sample pre-treatment and extraction of a panel of 49 drugs of abuse from human hair, using Biotage® Lysera for matrix m...
14 September 2018Plasma renin activity (PRA) determination is used in the diagnosis of primary aldosteronism, an important cause of secondary hypertension (high blood pressure). Concomitant measurement of both aldo...
24 November 2017This application note describes a supported liquid extraction protocol for the extraction of three acidic catecholamine metabolites (vanillylmandelic acid, homovanillic acid and 5-hydroxyindoleacet...
19 May 2017The method described in this application note achieves high reproducible extraction recoveries of the peptides oxytocin and vasopressin from serum using a fast, simple EVOLUTE® EXPRESS Load-Was...
15 February 2017This application note describes the extraction of benzodiazepine compounds from oral fluid matrix collected with the NeoSal™ devices, prior to GC/MS analysis. The protocol described ...
10 February 2017The method described in this application from Biotage Labs demonstrates high, reproducible recovery of teicoplanin from human plasma. Samples were extracted using an EVOLUTE® EXPRESS ABN 30 mg ...
08 February 2017This application note describes the extraction of cocaine and selected metabolites from oral fluid matrix following the collection with the NeoSal™ devices, prior to GC/MS analysis. ...
12 January 2017This application note describes the extraction of opiate compounds from oral fluid matrix collected using the NeoSal™ devices, prior to GC/MS analysis. This application note des...
27 September 2016Recovery profiles from manual and automated supported liquid extraction protocols were put side by side in a study on drugs of abuse in blood and urine matrices. Data reliability in forens...
25 November 2014This application note describes the extraction of 47 drugs of abuse from oral fluid matrix after sampling via Quantisal collection devices prior to UPLC-MS/MS analysis. Oral fluid collecti...
23 October 2014A simplified method for screening metanephrine and normetanephrine proves as effective as the current gold standard. It is anticipated that this time-saving and sensitive SPE-LC-ESI-MS/MS...
Question:
Answer:
On average, an extraction can take anywhere from 15 - 20 minutes, with dirtier samples taking longer. The total run time will also be a function of the number of Pre-wet and Rinse steps that have been programmed into the method.
Browse more questions and answers >Biotage® SPE Dry 96 and SPE Dry 96 Dual Sample Concentrators are suitable for evaporation of microplate samples across a broad range of formats. By delivering heated gas above and below each well, SPE Dry 96 systems dry samples quickly maintaining tight temperature control at user selected settings. Designed for high throughput sample processing, SPE Dry systems have simple front panel controls and use removable gas delivery assemblies for fast adjusting and cleaning.
Biotage® SPE Dry is designed with novel technology and a simple interface to produce uniform and reproducable evaporation. The design has a small footprint to fit easily in the fume hood. The heating mechanism is designed to rapidly heat without overshooting the temperature, preventing degradation of temperature sensitive compounds. Standard SPE Dry 96 and SPE Dry 96 Dual systems are supplied with stainless steel needles. For high purity work, or applications that require particularly aggressive solvents, PTFE coated needles are available. Both needle types can be individually replaced should they become damaged or corroded. SPE Dry is available in single or dual format and adapts easily to 24-, 48-, 96-, and 384-well microplate formats.
Efficient solvent evaporation is facilitated by heated gas flow from above and below the plate(s). Optimum temperature and gas flow conditions are set by the user. Evaporation conditions for the upper and lower heads can be controlled independently.
These easy to use systems have simple front panel controls for regulating gas temperature and flow rate. Valuable fume hood space is saved with the compact design.
The removable heads are easy to clean and can be sonicated as a whole unit. Removable needles are easy to replace.
SPE Dry 96 accommodates one microplate, while SPE Dry 96 Dual is a two-microplate system. The standard systems are supplied with stainless steel needles and are compatible with 24 and 96-well microplates. Higher density arrangements are also available for 384-well microplates. PTFE coated needle assemblies are available for use with aggressive solvents.
Part No. | Description | Product type | Pack Size | Price | ||
![]() |
SD-9600-DHS-EU | Biotage® SPE Dry 96 Sample Concentrator System 220 V | Instruments | 1 | Log in for price | |
SD-9600-DHS-NA | Biotage® SPE Dry 96 Sample Concentrator System 110 V | Instruments | 1 | Log in for price | ||
SD-9600-DHS-T-EU | Biotage® SPE Dry 96 System PTFE (Top Head Only) 220 V | Instruments | 1 | Log in for price | ||
SD-9600-DHS-T-NA | Biotage® SPE Dry 96 System PTFE (Top Head Only) 110 V | Instruments | 1 | Log in for price | ||
![]() |
SD2-9600-DHS-EU | Biotage® SPE Dry 96 Dual Sample Concentrator System 220 V | Instruments | 1 | Log in for price | |
![]() |
SD2-9600-DHS-NA | Biotage® SPE Dry 96 Dual Sample Concentrator System 110 V | Instruments | 1 | Log in for price | |
![]() |
SD2-9600-DHS-T-EU | Biotage® SPE Dry 96 Dual System PTFE (Top Head Only) 220 V | Instruments | 1 | Log in for price | |
![]() |
SD2-9600-DHS-T-NA | Biotage® SPE Dry 96 Dual System PTFE (Top Head Only) 110 V | Instruments | 1 | Log in for price |