EVOLUTE® EXPRESS Sample Preparation products provide robust, reliable SPE, giving ultra pure extracts and high analyte recoveries. Developed specifically for analyte quantification by LC-MS/MS, EVOLUTE sorbents provide a highly effective solution to the problems of ion suppression and matrix effects.
Eliminate conditioning and equilibration with EVOLUTE EXPRESS load-wash-elute SPE
Chemical description | Water wettable polystyrene-divinylbenzene incorporating non-ionisable hydroxyl groups |
Sorbent type | Reversed phase (non-polar), wettable, with no secondary interactions |
Average particle size | 30 µm, 50 µm |
Pore Diameter | 40 Å |
This application note describes the extraction of a panel of estrogenic hormones from human serum using EVOLUTE® EXPRESS ABN solid phase extraction plates prior to LC/MS analysis. The simple sample preparation procedure delivers clean extracts and analyte recoveries greater than 90% with RSDs lower than 5% for all analytes. Linearity of greater than 0.99 is achieved for Estrone (E1) and Estradiol (E2) from 5–2000 pg/mL, and 50–20000 pg/mL for Estriol (E3). No derivatization is required, and detection limits are enhanced using a fluorinated mobile phase.
Tags: 96-well plate,
Application Notes,
Clinical,
English,
Estradiol,
Estriol,
Estrogens,
Estrone,
LC-MS/MS,
Serum,
Steroid,
Steroid Hormones
Analysis of drug panels in urine samples can be challenging, and the trend towards larger panels including multiple drug classes compounds the issues faced during method development.
This white paper examines a number of aspects of sample preparation, and their impact on the success of subsequent LC-MS/MS analysis of broad urine panels.
Section 1 examines the applicability of various sample preparation techniques: supported liquid extraction, reverse phase SPE and mixed-mode SPE, to the various classes of drugs extracted. In addition, hydrolysis approaches: enzyme type and protocol used (time, temperature), are compared.
Mixed-mode reverse phase/cation exchange SPE is widely used for extraction of basic drug classes from urine, but the inclusion of drugs and metabolites that exhibit ‘non-typical’ functionality within urine panels can be problematic. Section 2 examines the impact of various parameters (interference wash strength, elution solvent composition) on analyte retention, elution and extract cleanliness with particular focus on zwitterionic (gabapentin, pregabalin) and non-ionic (carisoprodol, meprobamate) drugs.
Tags: 11-nor- Δ9-carboxy tetrahydrocannabinol (THC-COOH),
6-acetylmorphine (MAM),
7-Aminoclonazepam,
96-well plate,
Alprazolam,
Amitriptyline,
Amphetamine,
Amphetamines,
Anaesthetic,
Anticonvulsant,
Application Notes,
Barbiturates,
Benzodiazepines,
Benzoylecgonine,
Buprenorphine,
Butalbital,
Cannabinoid,
Carbamate hypnotic,
Carbamate muscle relaxant,
Carbamates,
Carisoprodol,
Chlordiazepoxide,
Clinical,
Clonazepam,
Cocaine,
Cocaines,
Codeine,
Diazepam,
Dihydrocodeine (DHC),
EDDP,
English,
Fentanyl,
Forensic,
Gabapentin,
Hallucinogen,
Hydrocodone,
Hydrolysed urine,
Hydromorphone,
Ketamine,
LC-MS/MS,
Lorazepam,
MDMA,
Meperidine,
Meprobamate,
Methadone,
Methamphetamine,
Morphine,
N-des-tapentadol,
Naloxone,
Norbuprenorphine,
Nordiazepam,
Norfentanyl,
Norhydrocodone,
Norketamine,
Normeperidine,
Noroxymorphone,
Norpropoxyphene,
Nortryptiline,
O-desmethyltramadol,
Opiates,
Opioid,
Opioid agonist,
Oxazepam,
Oxycodone,
Oxymorphone,
Pentobarbital,
Phencyclidine,
Phencyclidine (PCP),
Phenobarbital,
Pregabalin,
Product Notes,
Ritalinic acid,
Secobarbital,
Stimulants,
Sympathomimetic amine,
THC metabolites,
THC-COOH,
Tapentadol,
Temazepam,
Tramadol,
Tricyclic Antidepressant,
White Papers,
Zolpidem,
Zolpidem-phenyl-4-COOH,
z-drugs,
α-OH alprazolam
This application note describes the extraction of a panel of 19 steroid hormones from human urine using EVOLUTE® EXPRESS ABN solid phase extraction plates prior to LC-MS/MS analysis. The simple sample preparation procedure delivers clean extracts and analyte recoveries greater than 75% with RSDs lower than 5% for most analytes. Linearity of greater than 0.999 is achieved for all analytes in the range 1–1000 pg/mL.
Manual and automated (using Biotage Extrahera) extraction protocols are detailed.
Tags: 11-deoxycorticosterone,
17-OH-Pregnenolone,
17-alpha-estradiol,
17-alpha-hydroxyprogesterone,
17-beta-estradiol,
18-OH-Corticosterone,
21-deoxycortisol,
96-well plate,
Aldosterone,
Androstenedione,
Application Notes,
Clinical,
Corticosterone,
Cortisol,
Cortisone,
DHEA (dehydroepiandrosterone,
DHEAS,
Dihydrotestosterone (DHT),
English,
Estrone,
Hormone,
Hormones,
LC-MS/MS,
Pregnenolone,
Progesterone,
Steroid,
Steroid Hormones,
Steroid metabolite,
Steroids,
Testosterone,
Urine
This application note describes the extraction of a panel of 19 steroid hormones from human serum using EVOLUTE® EXPRESS ABN solid phase extraction plates prior to LC/MS analysis. The simple sample preparation procedure delivers clean extracts and analyte recoveries greater than 80% with RSDs lower than 10% for the majority of analytes. Linearity of >0.99 is achieved for all analytes in the range 5–5000 pg/mL.
The application note includes details on automation of the extraction method using Biotage® Extrahera.
Tags: 11-deoxycorticosterone,
11-deoxycortisol,
17-OH-Pregnenolone,
17-alpha-hydroxyprogesterone,
18-OH-Corticosterone,
21-deoxycortisol,
96-well plate,
Aldosterone,
Androstenedione,
Application Notes,
Clinical,
Corticosterone,
Cortisol,
Cortisone,
DHEA (dehydroepiandrosterone,
DHEAS,
Dehydroepiandrosterone (DHEA),
Dihydrotestosterone (DHT),
English,
Estradiol,
Estrogens,
Estrone,
Extrahera,
Hormone,
Hormones,
LC-MS/MS,
Pregnenolone,
Progesterone,
Serum,
Steroid,
Steroid Hormones,
Steroid metabolite,
Steroids
This application note describes the simultaneous extraction of aldosterone at low (< 25pg/mL) concentration and angiotensin I and II from plasma, with the potential to improve throughput and reduce time and costs in PRA determination.
Tags: 96-well plate,
Aldosterone,
Angiotensin I,
Angiotensin II,,
Application Notes,
Clinical,
English,
Extrahera,
LC-MS/MS,
Peptides,
Plasma,
Steroid Hormones
This application note describes the fully automated extraction of carboxy-THC from urine, following base hydrolysis prior to GC/MS analysis. The method was automated using Biotage® ExtraheraTM, configured for use with EVOLUTE EXPRESS ABN columns.
The method delivers clean extracts and analyte recovery of 90% with RSD lower than 10% for carboxy-THC and its deuterated internal standard. Using the Biotage® ExtraheraTM, 24 samples were extracted in approximately 38 minutes. The limit of quantitation of 2 ng/mL is below the SAMHSA/ EWDTS confirmation cut off of 15 ng/mL for workplace testing applications.
Tags: 11-nor- Δ9-carboxy tetrahydrocannabinol (THC-COOH),
Application Notes,
Column,
English,
Extrahera,
Forensic,
GC-MS,
Hydrolysed urine,
THC metabolites,
THC-COOH
This application note describes a solid phase extraction protocol for the extraction of three catecholamine metabolites (vanillylmandelic acid, homovanillic acid and 5-hydroxyindoleacetic acid) from plasma prior to LC-MS/MS detection. The method described in this application achieves high reproducible recoveries and excellent linearity (>0.99) in the range 10-200 ng/mL.
Tags: 5-hydroxyindoleacetic acid (5-HIAA) ,
96-well plate,
Acidic catecholamine metabolites,
Application Notes,
Clinical,
English,
Homovanillic acid (HVA),
LC-MS/MS,
Plasma,
Vanillylmandelic acid (VMA)
Whether you need targeted methods for analytes such as Vitamin D metabolites in serum, or methods suitable for extraction of a wide panel of drugs and metabolites from urine, sample preparation before analysis is essential.
This compendium highlights a selection of clinical sample preparation applications from Biotage.
Tags: Alcohol metabolite,
Application Notes,
Biomarker,
Brochures,
Catecholamines,
Clinical,
English,
Hormone,
Hormones,
Pain Management,
Peptides,
Product Notes,
Steroid,
Steroid Hormones,
Steroid metabolite,
Steroids,
Thyroid Hormone,
Tobacco Specific Nitrosamines (TSNAs),
Vitamin D,
Vitamins,
Water Soluble Vitamins
The method described in this application note achieves high reproducible extraction recoveries of the peptides oxytocin and vasopressin from serum using a fast, simple EVOLUTE® EXPRESS Load-Wash-Elute SPE procedure.
Extraction from serum was performed using EVOLUTE EXPRESS ABN 96-well plates, utilizing a highly aqueous elution solvent, and minimizing co-extractable material in the form of proteins, lipids and phospholipids.
Tags: 96-well plate,
Application Notes,
Clinical,
English,
LC-MS/MS,
Oxytocin,
Peptides,
Pharma,
Serum,
Vasopressin
The method described in this application note achieves high reproducible extraction recoveries of vitamin B7 from serum while minimizing co-extractable material in the form of proteins, lipids and phospholipids. Serum is extracted using the EVOLUTE® EXPRESS ABN 96-well plate.
Tags: 96-well plate,
Application Notes,
Biotin,
Clinical,
English,
Extrahera,
LC-MS/MS,
Serum,
Vitamin B7,
Vitamins,
Water Soluble Vitamins
This procedure is recommended for the extraction of a variety of diuretics from urine using non-polar polymeric SPE. The analyte suite includes thiazides, carbonic anhydrase inhibitors, loop and potassium sparring diuretics, with wide ranging pKa and logP values.
Tags: Acetazolamide,
Amiloride,
Application Notes,
Bendoflumethiazide,
Bumetanide,
Clinical,
Column,
Diuretics,
Ethacrynic acid,
Furosemide,
Hydrochlorothiazide,
Hydroflumethiazide,
LC-MS/MS,
Methazolamide,
Spironolactone,
Urine
This procedure is recommended for the extraction of a variety of pharmaceuticals from water using non-polar polymeric SPE. These pharmaceuticals were identified as potential environmental contaminants by the Environment Agency.
Pharmaceuticals, waste water, antibiotics, EVOLUTE,
Tags: Application Notes,
Atenolol,
Carbamazepine,
Citalopram,
Column,
Diclofenac,
Environmental,
Erythromycin,
Fluoxetine,
Fluvoxamine,
HPLC,
Ibuprofen,
Labetalol,
Mefenamic,
Metoprolol,
Oxprenolol,
Paroxetine,
Pharmaceuticals,
Propranolol,
Sotalol,
Sulfamethoxazole,
Trimethoprim,
Water
Whether you need targeted methods for analytes such as Vitamin D metabolites in serum, or methods suitable for extraction of a wide panel of drugs and metabolites from urine, sample preparation before analysis is essential.
This compendium highlights a selection of clinical sample preparation applications from Biotage.
Tags: Alcohol metabolite,
Application Notes,
Biomarker,
Brochures,
Catecholamines,
Clinical,
English,
Hormone,
Hormones,
Pain Management,
Peptides,
Product Notes,
Steroid,
Steroid Hormones,
Steroid metabolite,
Steroids,
Thyroid Hormone,
Tobacco Specific Nitrosamines (TSNAs),
Vitamin D,
Vitamins,
Water Soluble Vitamins
In this catalog product information is displayed with easy-to-follow application details and supporting documentation. Ordering information is found following each product listing
Tags: Catalogs
Customer Case: Japan Frozen Foods Inspection Corporation.
The Japan Frozen Foods Inspection Corporation (JFFIC) made the transition from traditional mouse
testing of shellfish toxins, to instrumental analysis by developing original methods. In the sample
preparation procedure JFFIC uses EVOLUTE® ABN hydrophilic/hydrophobic SPE columns from Biotage.
Tags: Customer Cases
EVOLUTE® EXPRESS Solid Phase Extraction products
from Biotage are designed for all your sample
preparation challenges. Whether you are working in the field of bio-analysis during drug development, clinical or forensic
toxicology, or with the diversity of samples in food
safety and environmental applications, the tools and
methods used for sample preparation have a clear
impact on productivity. This user guide contains information about choosing the correct EVOLUTE EXPRESS product for your application and optimizing your methodology for best results.
Tags: 96-well plate,
Clinical,
Column,
English,
Environmental,
Food,
Forensic,
Manuals & User Guides,
On-line SPE,
Pharma
QuickStart Guide to SPE
Tags: English,
Manuals & User Guides
•Extends the range of acidic, basic and neutral compounds that can be extracted using a single generic method, increasing method development productivity•Has an optimized pore structure which reduces the extraction of endogenous matrix components, and leads to cleaner extracts that give fewer matrix effects in LC-MS/MS analysis•Has optimized physical and chemical characteristics that improve reliability of SPE procedures•Has no secondary interactions, allowing the use of pure organic elution solvent to give high recoveries of very low drug concentrations
Tags: Manuals & User Guides
Laboratory chemical
Not for therapeutic or diagnostic use
Tags: English,
Material Safety Data Sheets
Laboratory chemical
Not for therapeutic or diagnostic use
Tags: English,
Material Safety Data Sheets
nvestigate different water wettable polymeric solid phase extraction sorbents for different analytes based analyte functional groups, pKa, and hydrophobicity, and reduce extraction time and increase throughput by eliminating SPE conditioning and equilibration steps.
Tags: 96-well plate,
Amitriptyline,
Atenolol,
Bretylium,
Clinical,
Diclofenac,
Ketoprofen,
LC-MS/MS,
Mefenamic acid,
Metoprolol,
Pharmaceuticals,
Posters,
Prednisolone,
Quinidine,
Sulindac,
Urine
Compare and choose sample clean-up options for a panel of endogenous steroids in serum prior to quantitation by LC-MS based on ease of use, compounds of interest and desired limits of quantitation (LOQs).
Tags: 96-well plate,
Forensic,
LC-MS/MS,
Posters,
Serum,
Steroid Hormones
GC/MS is still a mainstay in forensic analysis for drugs of abuse testing in urine. Historically silica-based solid phase extraction (SPE) columns have been used for these target analytes, the exact choice being dependent on drug functionality. The primary urinary target to prove cannabis using is the metabolite 11-nor-9-carboxy-Δ9 tetrahydrocannabinol.
Tags: 11-nor- Δ9-carboxy tetrahydrocannabinol (THC-COOH),
96-well plate,
Drugs of Abuse,
Forensic,
GC-MS,
Posters,
Urine
GC/MS is still a mainstay in forensic analysis for drugs of abuse
testing in urine. Historically silica-based solid phase extraction
(SPE) columns have been used for these target analytes, the exact
choice being dependent on drug functionality. This poster aims to compare various sample preparation techniques for this analysis. ASMS, 2020.
Tags: 11-nor- Δ9-carboxy tetrahydrocannabinol (THC-COOH),
96-well plate,
Drugs of Abuse,
Forensic,
GC-MS,
Posters,
Urine
Monitoring estrogenic compounds such as Estrone (E1), Estradiol
(E2), and Estriol (E3) in human serum is essential in clinical research and diagnostics. Detection in men, post-menopausal women and children requires very low limits of detection (LODs) which can be challenging.
Tags: 96-well plate,
Clinical,
Estrogens,
LC-MS/MS,
Posters,
Serum
Traditionally the analysis of aldosterone and angiotensin (for plasma renin activity measurement) are performed separately. However, the relationship of the aldosterone-to-renin-ratio is a very useful tool to help define the cause of secondary hypertension. This poster compares sample preparation options for the simultaneous extraction of Angiotensin I, II and Aldosterone from plasma.
MSACL EU 2018
MSACL NA 2019
Tags: 96-well plate,
Aldosterone,
Angiotensin I,
Angiotensin II,,
Clinical,
English,
Hormone,
Hormones,
LC-MS/MS,
Peptides,
Posters,
Steroid,
Steroid Hormones,
Steroids
This poster compares sample preparation options for the extraction of a panel of endogenous steroids from serum. LC-MS/MS parameters were investigated for increased sensitivity: MRM transitions, chromatography and mobile phase additives for use with positive and negative ionisation modes.
Particular emphasis was placed on the sample preparation to
provide high reproducible recoveries whilst minimizing matrix effects and co-extracted materials such as proteins and phospholipids. Solid phase extraction was compared to supported liquid extraction in terms of recoveries, ion suppression, phospholipid content, calibration curve performance and overall sensitivity.
MSACL EU 2018
Tags: 96-well plate,
Clinical,
English,
Hormone,
Hormones,
LC-MS/MS,
Posters,
Steroid,
Steroid Hormones,
Steroid metabolite,
Steroids
Urine drug testing to support pain management is a mainstay of the clinical toxicology laboratory. Reduced reimbursement has continued to put increasing pressure on laboratories. Many toxicology labs are moving to larger drug panels to increase throughput and efficiency, while reducing turn-around-time and cost.
Tags: Clinical,
LC-MS/MS,
Pharma,
Posters
This poster evaluates 3 different sample preparation approaches (ISOLUTE SLE+, EVOLUTE EXPRESS ABN, EVOLUTE EXPRESS CX) for extraction of large multi-drug urine panels.
Each approach is assessed in terms of suitability for extraction of analytes with different different properties (pka, LogP etc).
ASMS 2017
Tags: 11-nor- Δ9-carboxy tetrahydrocannabinol (THC-COOH),
6-acetylmorphine (MAM),
7-Aminoclonazepam,
96-well plate,
Alprazolam,
Amitriptyline,
Amphetamine,
Amphetamines,
Analgesics,
Barbiturates,
Benzodiazepines,
Benzoylecgonine,
Buprenorphine,
Butalbital,
Cannabinoid,
Carbamate hypnotic,
Carbamate muscle relaxant,
Carisoprodol,
Chlordiazepoxide,
Clinical,
Clonazepam,
Cocaine,
Cocaines,
Codeine,
Diazepam,
Dihydrocodeine (DHC),
Drugs of Abuse,
EDDP,
English,
Fentanyl,
Forensic,
Gabapentin,
Hydrocodone,
Hydrolysed urine,
Hydromorphone,
Ketamine,
LC-MS/MS,
Lorazepam,
MDMA,
Meperidine,
Meprobamate,
Methadone,
Methamphetamine,
Morphine,
N-des-tapentadol,
Naloxone,
Norbuprenorphine,
Nordiazepam,
Norfentanyl,
Norhydrocodone,
Norketamine,
Normeperidine,
Nortryptiline,
Opiates,
Opioid,
Oxazepam,
Oxycodone,
Oxymorphone,
Pain Management,
Phencyclidine,
Phenobarbital,
Posters,
Pregabalin,
Ritalinic acid,
Secobarbital,
Tapentadol,
Temazepam,
Tramadol,
Urine,
Zolpidem,
Zolpidem-phenyl-4-COOH,
z-drugs,
α-OH alprazolam
This poster investigates the selectivity of polymer-based solid phase extraction sorbents and rapid extraction of clinical matrices, matrix interference reduction and improved analyte detection.
ASMS 2017
Tags: 96-well plate,
Clinical,
English,
Oxytocin,
Peptides,
Pharma,
Posters,
Serum,
Vasopressin
Part of the B complex group of water soluble vitamins, vitamin B7 (Biotin) is involved in various metabolic processes within the body. It is a small polar carboxylic acid which can present challenges in bioanalysis. This poster discusses the impact of optimization of various parts of the method development process to maximize
sensitivity allowing low level analysis of vitamin B7 from human serum.
MSACL 2017, Palm Springs
ASMS 2017, Indianapolis
Tags: 96-well plate,
Biotin,
Clinical,
English,
LC-MS/MS,
Posters,
Serum,
Vitamin B7,
Vitamins,
Water Soluble Vitamins
This poster includes a simple Load-Wash-Elute solid phase extraction method using EVOLUTE EXPRESS WCX, for extraction of aminoglycoside antibiotics from a range of meat, milk and egg samples.
The sample preparation method is automated using Biotage Extrahera, with fast, sensitive analysis utilizing HILIC-MS/MS with MRM Spectrum Mode for ID confirmation (Shimadzu LCMS-8060).
ASMS 2017
Tags: 96-well plate,
Amikacin,
Aminoglycoside antibiotics,
Apramycin,
Dihydrostreptomycin,
Eggs,
English,
Extrahera,
Food,
Gentamicin,
Gentamicin C1,
Gentamicin C1a,
Gentamicin C2,
Hygromycin B,
Kanamycin,
LC-MS/MS,
Meat,
Milk,
Neomycin,
Netilmicin,
Paromomycin,
Posters,
Sisomycin,
Spectinomycin,
Streptomycin,
Tobramycin,
Veterinary drugs
This poster describes a simple solid phase extraction method using EVOLUTE® EXPRESS ABN columns for the extraction of the marine toxins okadaic acid (OA), dinophysistoxins (DTX1 and DTX2), ciguatoxin 3C (CTX3C) and tetrodotoxin (TTX).
ASMS 2017
Tags: Ciguatoxin 3C (CTX3C),
Column,
Diarrhetic Shellfish Poisoning (DSP) Toxins,
Dinophysistoxin 1 (DTX1),
Dinophysistoxin 2 (DTX2),
English,
Food,
LC-MS/MS,
Marine Toxins,
Okadaic Acid (OA),
Paralytic Shellfish Poisoning (PSP) Toxins,
Posters,
Tetrodotoxin (TTX)
EVOLUTE® EXPRESS SPE columns and plates combine sorbent wettability with optimized SPE components, allowing better flow consistency and in many cases eliminating the need for SPE column conditioning; thus simplifying and reducing extraction processing. This poster compares the performance of various EVOLUTE EXPRESS column chemistries using 10-500 mg bed weights, in order to investigate whether sorbent conditioning and equilibration steps are truly required.
ASMS 2015
Tags: Acidic,
Amitriptyline,
Atenolol,
Benzenesulfonic acid,
Bretylium,
Clinical,
Column,
Diethyldithiophosphate (DEDTP),
Dimethylthiophosphate (DMTP),
English,
Extrahera,
Forensic,
Hexanesulfonic acid,
Ketoprofen,
LC-MS/MS,
Metoprolol,
Mianserin,
Organophosphate Pesticide,
Over the counter pharmaceuticals,
Pain Management,
Pharma,
Pharmaceuticals,
Posters,
Prednisolone,
Procainamide,
Quaternary Amines,
Quinidine,
Salbutamol,
Sulindac,
Tricyclic Antidepressant,
Urine,
β-blockers
This poster focuses on the different strategies that can be employed when using EVOLUTE SPE sorbents (with both single and dual retention mechanisms) to reduce or eliminate residual phospholipids in sample extracts.
HPLC 2014
Tags: 96-well plate,
Clinical,
English,
Forensic,
LC-MS/MS,
Pharma,
Posters
This poster uses gel electrophoresis data to visually illustrate the amount of residual protein in extracts prepared using protein precipitation, supported liquid extraction and various silica and polymer based SPE approaches.
HPLC2014
Tags: Biological fluids,
English,
HPLC,
LC-MS/MS,
Plasma,
Posters
This poster describes the use of EVOLUTE® ABN and EVOLUTE® EXPRESS ABN for the fast and efficient extraction of a diverse mixture of peptides spiked into biological matrices.
Pittcon 2014
Tags: 96-well plate,
ACTH (1-24),
Angiotensin Fragment 1-7,
Angiotensin II,,
Clinical,
Elafin,
Endorphin,
English,
Glycoprotein myelin,
Helicobacter pylori (2-20),
LC-MS/MS,
Peptides,
Pharma,
Plasma,
Posters,
Serum,
Vasoactive Intestinal Fragment 1-12
This poster outlines a new method for the extraction of a mixture of peptides from plasma using resin based SPE. Initial method optimization was performed using EVOLUTE ABN before comparison to the streamlined approach without plate conditioning and equilibration using EVOLUTE EXPRESS ABN. Presented at EBF 2012.
EBF, EBF 2012, Peptide, ABN, SPE, Polymer, Polymeric,
Tags: ACTH (1-24),
Alpha-Endorphin,
Angiotensin Fragment 1-7,
Angiotensin II,,
Elafin,
Helicobacter pylori (2-20),
LC-MS/MS,
Myelin Glycoprotein fragment (35-55) rat,
Peptides,
Pharma,
Plasma,
Posters,
Vasoactive Intestinal Fragment 1-12
Analysis of drug panels in urine samples can be challenging, and the trend towards larger panels including multiple drug classes compounds the issues faced during method development.
This white paper examines a number of aspects of sample preparation, and their impact on the success of subsequent LC-MS/MS analysis of broad urine panels.
Section 1 examines the applicability of various sample preparation techniques: supported liquid extraction, reverse phase SPE and mixed-mode SPE, to the various classes of drugs extracted. In addition, hydrolysis approaches: enzyme type and protocol used (time, temperature), are compared.
Mixed-mode reverse phase/cation exchange SPE is widely used for extraction of basic drug classes from urine, but the inclusion of drugs and metabolites that exhibit ‘non-typical’ functionality within urine panels can be problematic. Section 2 examines the impact of various parameters (interference wash strength, elution solvent composition) on analyte retention, elution and extract cleanliness with particular focus on zwitterionic (gabapentin, pregabalin) and non-ionic (carisoprodol, meprobamate) drugs.
Tags: 11-nor- Δ9-carboxy tetrahydrocannabinol (THC-COOH),
6-acetylmorphine (MAM),
7-Aminoclonazepam,
96-well plate,
Alprazolam,
Amitriptyline,
Amphetamine,
Amphetamines,
Anaesthetic,
Anticonvulsant,
Application Notes,
Barbiturates,
Benzodiazepines,
Benzoylecgonine,
Buprenorphine,
Butalbital,
Cannabinoid,
Carbamate hypnotic,
Carbamate muscle relaxant,
Carbamates,
Carisoprodol,
Chlordiazepoxide,
Clinical,
Clonazepam,
Cocaine,
Cocaines,
Codeine,
Diazepam,
Dihydrocodeine (DHC),
EDDP,
English,
Fentanyl,
Forensic,
Gabapentin,
Hallucinogen,
Hydrocodone,
Hydrolysed urine,
Hydromorphone,
Ketamine,
LC-MS/MS,
Lorazepam,
MDMA,
Meperidine,
Meprobamate,
Methadone,
Methamphetamine,
Morphine,
N-des-tapentadol,
Naloxone,
Norbuprenorphine,
Nordiazepam,
Norfentanyl,
Norhydrocodone,
Norketamine,
Normeperidine,
Noroxymorphone,
Norpropoxyphene,
Nortryptiline,
O-desmethyltramadol,
Opiates,
Opioid,
Opioid agonist,
Oxazepam,
Oxycodone,
Oxymorphone,
Pentobarbital,
Phencyclidine,
Phencyclidine (PCP),
Phenobarbital,
Pregabalin,
Product Notes,
Ritalinic acid,
Secobarbital,
Stimulants,
Sympathomimetic amine,
THC metabolites,
THC-COOH,
Tapentadol,
Temazepam,
Tramadol,
Tricyclic Antidepressant,
White Papers,
Zolpidem,
Zolpidem-phenyl-4-COOH,
z-drugs,
α-OH alprazolam
Whether you need targeted methods for analytes such as Vitamin D metabolites in serum, or methods suitable for extraction of a wide panel of drugs and metabolites from urine, sample preparation before analysis is essential.
This compendium highlights a selection of clinical sample preparation applications from Biotage.
Tags: Alcohol metabolite,
Application Notes,
Biomarker,
Brochures,
Catecholamines,
Clinical,
English,
Hormone,
Hormones,
Pain Management,
Peptides,
Product Notes,
Steroid,
Steroid Hormones,
Steroid metabolite,
Steroids,
Thyroid Hormone,
Tobacco Specific Nitrosamines (TSNAs),
Vitamin D,
Vitamins,
Water Soluble Vitamins
In diesem Whitepaper sollen verschiedene Aspekte der
Probenvorbereitung beleuchtet werden. Dazu gehört auch der
Einfluss der Probenvorbereitung auf den Erfolg der nachfolgenden
LC-MS/MS-Analyse von breit angelegten Urin-Panels.
Tags: White Papers
Analysis of drug panels in urine samples can be challenging, and the trend towards larger panels including multiple drug classes compounds the issues faced during method development.
This white paper examines a number of aspects of sample preparation, and their impact on the success of subsequent LC-MS/MS analysis of broad urine panels.
Section 1 examines the applicability of various sample preparation techniques: supported liquid extraction, reverse phase SPE and mixed-mode SPE, to the various classes of drugs extracted. In addition, hydrolysis approaches: enzyme type and protocol used (time, temperature), are compared.
Mixed-mode reverse phase/cation exchange SPE is widely used for extraction of basic drug classes from urine, but the inclusion of drugs and metabolites that exhibit ‘non-typical’ functionality within urine panels can be problematic. Section 2 examines the impact of various parameters (interference wash strength, elution solvent composition) on analyte retention, elution and extract cleanliness with particular focus on zwitterionic (gabapentin, pregabalin) and non-ionic (carisoprodol, meprobamate) drugs.
Tags: 11-nor- Δ9-carboxy tetrahydrocannabinol (THC-COOH),
6-acetylmorphine (MAM),
7-Aminoclonazepam,
96-well plate,
Alprazolam,
Amitriptyline,
Amphetamine,
Amphetamines,
Anaesthetic,
Anticonvulsant,
Application Notes,
Barbiturates,
Benzodiazepines,
Benzoylecgonine,
Buprenorphine,
Butalbital,
Cannabinoid,
Carbamate hypnotic,
Carbamate muscle relaxant,
Carbamates,
Carisoprodol,
Chlordiazepoxide,
Clinical,
Clonazepam,
Cocaine,
Cocaines,
Codeine,
Diazepam,
Dihydrocodeine (DHC),
EDDP,
English,
Fentanyl,
Forensic,
Gabapentin,
Hallucinogen,
Hydrocodone,
Hydrolysed urine,
Hydromorphone,
Ketamine,
LC-MS/MS,
Lorazepam,
MDMA,
Meperidine,
Meprobamate,
Methadone,
Methamphetamine,
Morphine,
N-des-tapentadol,
Naloxone,
Norbuprenorphine,
Nordiazepam,
Norfentanyl,
Norhydrocodone,
Norketamine,
Normeperidine,
Noroxymorphone,
Norpropoxyphene,
Nortryptiline,
O-desmethyltramadol,
Opiates,
Opioid,
Opioid agonist,
Oxazepam,
Oxycodone,
Oxymorphone,
Pentobarbital,
Phencyclidine,
Phencyclidine (PCP),
Phenobarbital,
Pregabalin,
Product Notes,
Ritalinic acid,
Secobarbital,
Stimulants,
Sympathomimetic amine,
THC metabolites,
THC-COOH,
Tapentadol,
Temazepam,
Tramadol,
Tricyclic Antidepressant,
White Papers,
Zolpidem,
Zolpidem-phenyl-4-COOH,
z-drugs,
α-OH alprazolam
Two new application notes from Biotage describe both manual and automated procedures for sample pre-treatment and extraction of a panel of 19 steroid hormones from human urine, using EVOL...
14 February 2019A White Paper from Biotage Abstract Analysis of drug panels in urine samples can be challenging, and the trend towards larger panels including multiple drug classes compounds the issues f...
04 February 2019This video outlines Application AN894, where angiotensin and aldosterone are extracted in the same process using EVOLUTE® EXPRESS ABN.
19 November 2018Extraction of Oxytocin and Vasopressin from Serum Using EVOLUTE® EXPRESS ABN Prior to LC-MS/MS Analysis The method described in this application achieves high reproducible extraction r...
14 September 2018Plasma renin activity (PRA) determination is used in the diagnosis of primary aldosteronism, an important cause of secondary hypertension (high blood pressure). Concomitant measurement of both aldo...
28 August 2018These two new application notes from Biotage describe the fully automated extraction of carboxy-THC from urine, following base hydrolysis prior to GC/MS analysis. The methods were automated using B...
13 August 2018Biotage presented five new posters at the ASMS conference in San Diego this June. We've collected them all below for download. P177: Comparison of Sample Preparation Options for the Extr...
01 February 2018Four posters and a seminar on sample preparation developments from Biotage were presented at MSACL, Palm Springs in January, now made available to the public. Posters Extraction...
31 January 2018This application note describes a solid phase extraction protocol for the extraction of three catecholamine metabolites (vanillylmandelic acid, homovanillic acid and 5-hydroxyindoleacetic acid) fro...
08 November 2017This compendium highlights 43 clinical sample preparation applications from Biotage. Whether you need targeted methods for analytes such as Vitamin D metabolites in serum, or methods suitable for e...
24 October 2017This application note from Biotage describes a solid phase extraction (SPE) protocol for the extraction of the peptide desmopressin from human serum prior to LC-MS/MS analysis. Desmopressi...
02 October 2017Many toxicology labs are moving to larger drug panels to increase throughput and reduce turn-around-time and cost. Methods using LC-MS with 50 or more drugs and metabolites are increasingly common,...
05 July 2017This application note describes a mixed-mode weak cation exchange SPE protocol for the extraction of three catecholamines (epinephrine, norepinephrine and dopamine) and three metanephrine metabolit...
29 May 2017Polyfluorinated compounds (PFCs) such as PFOS (perfluorooctanesulfonic acid) and PFOA (perfluorooctanoic acid) are man-made fluorosurfactants. Due to their widespread industrial use and chemical st...
19 May 2017The method described in this application note achieves high reproducible extraction recoveries of the peptides oxytocin and vasopressin from serum using a fast, simple EVOLUTE® EXPRESS Load-Was...
20 April 2017Vitamin B7 (Biotin) is a water soluble vitamin necessary for cell growth. The method described in this application note achieves high reproducible extraction recoveries of vitamin B7 from serum whi...
14 March 2017A White Paper from Biotage Abstract Analysis of drug panels in urine samples can be challenging, and the trend towards larger panels including multiple drug classes compounds the issues f...
22 February 2017Four posters were presented at MSACL in Palm Springs, CA, 22-26 January 2017. P154: Method Optimization for the Low Level Detection of Vitamin B7 from Human Serum Using UPLC-MS/MS An...
10 February 2017The method described in this application from Biotage Labs demonstrates high, reproducible recovery of teicoplanin from human plasma. Samples were extracted using an EVOLUTE® EXPRESS ABN 30 mg ...
06 December 2016Could there be a sorbent for versatile sample preparation that doesn't need conditioning and equilibration? Actually, Biotage has developed five such sorbents in the EVOLUTE® EXPRESS family, an...
06 October 2016The Japan Frozen Foods Inspection Corporation (JFFIC) made the transition from traditional mouse testing of shellfish toxins, to instrumental analysis by developing original methods. In the sample ...
15 October 2015A new application note from Biotage describes an optimized method for extraction of the catecholamines dopamine, epinephrine and norepinephrine from human plasma. The extraction method utilizes the...
27 March 2015Biotage, pioneers in flash chromatography, started packing columns with silica for flash purification 30 years ago. Some of the first employees are still with us today. In this video, site director...
13 March 2015In a study aimed at determining the pharmacokinetic characteristics and metabolism of eprinomectin in cats, EVOLUTE® ABN plates were used to quantify eprinomectin B1a in plasma. A vali...
29 July 2014Buy your Biotage consumables through our website and shipping is free For a limited time, free shipping is applied to Biotage consumables orders through the Biotage website*. Let Biotage make orde...
10 July 2014Eight new posters by Biotage Scientists and collaborating groups have been presented at ASMS 2014, Baltimore, MD, USA. P81 A Reduced Workflow Method For The Extraction Of Vitamin B7 (bi...
30 June 2014Biotage is attending EPRW (European Pesticides and Residues Workshop) 2014 30th June - 3rd July 2014, Dublin, Ireland Read more at conference website http://eprw2014.com/
20 May 2014Four new posters by Biotage R&D and Application Scientists have been presented this week at HPLC 2014, New Orleans, LA, USA. The studies focus on clean-up of biofluids using different sa...
01 April 2014Biotage is attending the Annual Meeting of the German Society for Experimental and Clinical Pharmacology and Toxicology (DGPT) 1st - 3rd April 2014, Hannover, Germany Read more at the conference ...
11 January 2014Biotage is attending the 22nd Congress French Toxicology Society19th Meeting Society of Hair Testing Annual Meeting Belgian and Luxembourg Toxicological Society 11th-13th June 2014, Bordeuax, Fran...
28 August 2012EVOLUTE EXPRESS 96-Well SPE EVOLUTE EXPRESS® represents a leap forward in high throughput solid phase extraction. The EVOLUTE EXPRESS range of 96-well SPE plates combine powerful EVOLUTE sorbe...
28 August 2012Uppsala, Sweden, 28th August, 2012 Biotage® (STO: BIOT), a leading global supplier of solutions and technology for analytical and medicinal chemistry, introduced EVOLUTE® EXPRESS, a novel ...
18 April 2011Uppsala, Sweden – Biotage, a leading supplier of tools and technology for medicinal and analytical chemistry, today announced the further expansion of its successful family of sample preparat...
16 December 2010Biotage Announces an Easy, Cost-Effective Approach to the Analysis of Ethyl Glucuronide (EtG) in Urine for Clinical and Forensic Toxicology Laboratories Uppsala, Sweden – Biotage®...
23 February 2010Uppsala, Sweden, March 2, 2010– Biotage, a leading supplier of tools and technology for medicinal and analytical chemistry, today announced the further expansion of its successful family of p...
04 January 2008[2008-01-04] Biotage to Unveil New Advanced Sample Preparation Products at PITTCON 2008 Biotage, the leading supplier of tools and technology for medical and analytical chemistry, announce...
Question:
Is there an expiry (‘best before’) date for ISOLUTE and EVOLUTE sample preparation products?
Answer:
There is no fixed expiry date for these products.
All ISOLUTE and EVOLUTE products are packaged in inner metal laminate barrier bags, which provide an effective barrier to oxygen and moisture penetration. Recommended storage conditions are standard (see below).
We have no indications that the performance of non-bonded phase SPE sorbents is affected by long term storage, under recommended conditions.
We have no indications that the performance of bonded phase SPE sorbents is affected by long term storage, under recommended conditions.
Browse more questions and answers >EVOLUTE® ABN is a modified PS-DVB polymeric SPE phase for extraction of acidic, basic and neutral analytes. It's unique modified surface structure is water-wettable to promote robust, reliable sample preparation. A balanced combination of polar (hydrophilic) and non-polar (hydrophobic) interactions allows efficient extraction of analytes of wide ranging polarity. Available in a variety of formats, including modular and 96-well plates and SPE columns, EVOLUTE ABN is versatile and easy to use for applications ranging from drugs in biological fluids to pharmaceuticals in water.
EVOLUTE® ABN sorbent is available in EVOLUTE® EXPRESS 96-well plate and column formats for use with fast Load-Wash-Elute procedures. Eliminate traditional conditioning and equilibration and increase throughput without compromising performance.
EVOLUTE® sorbents have a narrow pore diameter, tailored to eliminate co-extraction of proteins from biofluids. Removal of proteins during sample preparation avoids transfer in to the analytical system, reducing matrix effects in LC-MS/MS, and avoiding contamination of the analytical column. This minimises the need for frequent backflushing and guard columns replacement.
EVOLUTE® ABN uses a single generic procedure suitable for a wide range of analytes in aqueous matrices. Without secondary interactions, pure organic elution solvents can be used, reducing evaporation time and providing optimal LC-MS/MS compatibility, making the transfer to analysis more efficient. See the EVOLUTE User Guide for a wealth of method optimisation information.
EVOLUTE ABN’s narrow particle size distribution provides consistent flow characteristics for a variety of sample matrices. Optimized packing techniques eliminate channelling, which can lead to analyte breakthrough.
Even viscous biofluids can be loaded onto EVOLUTE EXPRESS ABN products without the need for conditioning or equilibration, using fast load-wash-elute SPE.
The surface characteristics of every batch of EVOLUTE® ABN are quality controlled and tested to ensure consistency and reliability.
Part No. | Description | Product type | Pack Size | Price | ||
![]() |
600-0001-AXG | EVOLUTE® EXPRESS ABN 10 mg/1 mL (Tabless) | Consumables | 100 | Log in for price | |
![]() |
600-0003-AXG | EVOLUTE® EXPRESS ABN 30 mg/1 mL (Tabless) | Consumables | 100 | Log in for price | |
![]() |
600-0010-PX01 | EVOLUTE® EXPRESS ABN 10 mg Fixed Well Plate | Consumables | 1 | Log in for price | |
![]() |
600-0030-PX01 | EVOLUTE® EXPRESS ABN 30 mg Fixed Well Plate | Consumables | 1 | Log in for price | |
![]() |
610-0006-BXG | EVOLUTE® EXPRESS ABN 60 mg/3 mL (Tabless) | Consumables | 50 | Log in for price | |
![]() |
610-0010-BXG | EVOLUTE® EXPRESS ABN 100 mg/3 mL (Tabless) | Consumables | 50 | Log in for price | |
![]() |
610-0015-CXG | EVOLUTE® EXPRESS ABN 150 mg/6 mL (Tabless) | Consumables | 30 | Log in for price | |
![]() |
610-0050-CXG | EVOLUTE® EXPRESS ABN 500 mg/6 mL (Tabless) | Consumables | 30 | Log in for price | |
![]() |
650-0010-PX01 | EVOLUTE® EXPRESS SORBENT SELECTION 10 mg Fixed Well Plate | Consumables | 1 | Log in for price | |
![]() |
650-0030-PX01 | EVOLUTE® EXPRESS SORBENT SELECTION 30 mg Fixed Well Plate | Consumables | 1 | Log in for price |
Part No. | Description | Product type | Pack Size | Price | ||
![]() |
121-9620 | Biotage® VacMaster 96 Tabless 1 mL Column Holder | Accessories | 1 | Log in for price | |
![]() |
PPM-A96-CH | 1 mL (Tabless) Column Holder | Accessories | 1 | Log in for price |