This product was withdrawn on September 30th 2009.
System Capabilities | |
Reactor | 1 to 6 independent vessels – two size options |
100 mL (35 to 65 mL working volume) | |
1000 mL (350 to 650 mL working volume) | |
Wetted Material | Hastelloy® *and Kalrez ® (*Option for SS 316) |
Temperature | Ambient to 200 °C, Internal temperature control |
Independent temperatures, no vessel to vessel differential limit | |
Active cooling to reduce temperature | |
Stirring | 200 to 2000 RPM |
Gas Entrainment Impeller as standard | |
Pressure Control | 5 to 500 psi (0.5 to 34 bar) |
±1psi control to monitor gas consumption | |
Mole Consumption | RDS across reactors < 5% |
Range of accuracy 0.5 to 500 mmol/hr | |
Min reaction time to maintain accuracy is 30 minutes | |
Vent Rate | Down to 5 psi (0.35 bar) above ambient in 2 minutes |
System Requirements | |
Power | 208 to 240 VAC, 50/60 Hz |
Gas Supply | Optimized for 520 psi inlet |
Connections for 1/8” OD Stainless Steel 316 | |
Room Temperature | 15 to 30 °C (59 to 95 °F) |
Humidity | 30 to 70% - non-condensing |
Glovebox operation capable | |
Ventilation requirements | 85 feet /min (25 m/min) |
Interfaces | |
System control and data management | Supplied PC desktop with keyboard and mouse |
Interface | Ethernet communication to Control PC |
LAN | Computer supplied with onboard Ethernet card for LAN connectivity |
The Atlantis pressure scale-up workstation performs and optimizes gas/liq and gas/liq/solid, heterogeneous reactions with the unique ability to monitor live gas consumption. Process
Chemists can easily load experiments with push-button hardware and precisely control and monitor reactions with simple-to-use software. The Atlantis system controls reaction parameters
automatically to eliminate sample degradation and in addition, provides concise reaction data reports with live molar uptake rates for better analysis.
Tags: Product Notes
The Biotage® Atlantis pressure scale-up workstation optimizes gas/liquid and gas/liquid/solid, heterogeneous reactions with live gas consumption monitoring. Process chemists can easily load experiments with push-button hardware and precisely control reactions with simple-designed software.
The Biotage® Atlantis system controls reaction parameters automatically to eliminate sample degradation and in addition, provides concise reaction data reports with live molar uptake rates for better analysis.
The design is simple and robust. Quickly load and run up to six reactors in parallel with push button control, eliminating alignment and sealing problems. It’s easier than a typical single reactor system. The standard reactor comes in two sizes, 100 mL and 1 L, allowing chemists to configure any number (up to 6) and size reactor (100 ml or 1 L) to best suit their hydrogenation and pressure scale-up needs.
Building on the technology introduced with the Biotage® Endeavor™ reaction screening, Atlantis allows the chemists to quickly follow the reaction progress for each vessel with mole consumption monitoring. This additional data provides each scale-up group with Process Analytical Technology (PAT), giving new and rapid insight into reaction kinetics, selective versus complete reductions and reaction completeness or poisoning. Real-time access to this data allows groups to quickly decide which reaction methods to study and scale-up further.
Run up to six independent reactions in parallel with the Atlantis system. The modular design means chemists can choose to have unique inlet gasses for each reactor or tee them together for common inlets. Independent temperature control, stirring, pressure control and molar consumption monitoring are all part of each powerful reactor module.
The Atlantis system provides a simple-to-program Recipe Editor along with basic push-button operation. The system automatically generates a report summary upon completion of the experiment. In addition, for further, detailed data mining the Report Wizard can be used to quickly analyze experiments conducted on the same module or across several modules.